CombiDiagnost R90 Cross functional DRF system

CombiDiagnost R90

Cross functional DRF system

Product number:

709030

This remote controlled fluoroscopy system in combination with high-end digital radiography is designed for consistent, superb image quality and high room utilization, in a cost effective manner.

This remote controlled fluoroscopy system in combination with high-end digital radiography is designed for consistent, superb image quality and high room utilization, in a cost effective manner.

Информация за контакт

* Това поле е задължително

Данни за контакт

*
*
*
*

Данни за фирмата

*
*
*
*
*
*

Бизнес детайли

Като уточним причината Ви за връзка, ще можем да Ви предоставим по-добро обслужване.
*
*
*

Specifications Show all

Tube: SRM 0608 ROT GS 505
focal spot
0.6 /0.8
Anode heat storage capacity
800 kHU (593kJ)
Maximum voltage
125 kV (110 kV in GCF)
Geometry
Maximum patient weight
284 kg (626 lbs) without limitations
Tube column movement range
160 cm (63")
Table height
62 cm - 142 cm (24.4"-59.9")
Motorized compressor
3 kg - 15 kg (6.6 lbs - 33.1 lbs) compression force
Table tilt angle
-90°/+90°
Source to Image Distance (SID)
113 cm – 183 cm (44’’ to 72’’)
Generator
Fluoroscopy techniques
Pulsed fluoroscopy (PF), in-pulse controlled
Grid-controlled fluoroscopy (GCF), in-pulse controlled
Tube voltage flouroscopy
40 - 125 kV
Exposure techniques
Manual: kV-mAs or kV-mA-s
Automatic Exposure Control (AEC) - Intelligent Exporuse (IQX), In-Pulse controlled
Automatic kV reduction techniques
Tube voltage exposure
40 - 150 kV
Power
65 kW, 80kW optional
Ceiling Suspension
Ceiling height at SID 110 cm (44")
2.83 m to 3.21 m (8'8.3" - 10'5.9")
Type
Four-part telescopic column
Collimator
Motorized, automatic
Tube: SRO 33100 ROT380 (for CS)
Anode heat storage capacity
300 kHU (200kJ)
focal spot
0.6 /1.2
Maximum voltage
150 kV
Wireless detector: SkyPlate Large
Detector size
35 cm x 43 cm (14" x 17")
Active area
34.48 cm x 42.12 cm (13.6" x 16.6")
Image matrix size
2330 x 2846 pixel
Type
Digital Csl (Cesium Iodide) flat detector
Wireless detector: SkyPlate Small
Image matrix size
1500 x 1920 pixel
Active area
22.2 cm x 28.4 cm (8.7" x 11.2")
Detector size
24 cm x 30 cm (app. 10" x 12")
Type
Digital Csl (Cesium Iodide) flat detector
Tube: SRO 33100 ROT380
focal spot
0.6 /1.6
Maximum voltage
150 kV
Anode heat storage capacity
300 kHU (200kJ)
Dynamic Flat Detector
Acquisition mode pulsed fluoroscopy
Up to 20 per second
Pixel size
148 µm
Acquisition mode continious fluoroscopy
Up to 30 frames per second
Detector Size
43 cm x 43 cm (17"x17")
Image matrix size
2,874 pixel x 2,840 pixel
Digital vertical stand
Motorized tilting
Optional, -20° to +90°
Detector Size
SkyPlate detector
Vertical travel
30 cm - 180 cm (11.8" - 5'11")